Pyrolysis fuel.
In an accredited laboratory, two diesel engines treated with NTROPYX at 1:20,000 used 15% less fuel per kilowatt-hour. We make the next measurement on your pyrolysis fuel.
Measured in the laboratory.
Laboratory accredited by CNAS (L23122), with ILAC-MRA recognition. Reports of 26 March 2026. A dose rate of 1:20,000 means one litre of NTROPYX for 20,000 litres of fuel.
NTROPYX works on every fuel, pyrolysis fuel included.
Measured in the laboratory
−15.2% / −15.0%
On EN 590 road diesel and DMB marine diesel, the laboratory measured 15.2% and 15.0% less fuel per kWh at 1:20,000. We have not yet published a measurement on pyrolysis fuel.
Our approach
NTROPYX is a molecular combustion catalyst that combustion does not consume. It helps the engine burn the hydrocarbon more completely, whatever the fuel's origin. Our explanation, as owners of the technology: the catalyst acts at molecular scale and speeds up combustion. We call this “a restructuring at quantum scale”. The formulation is confidential. The laboratory does not rule on the mechanism. It measures the effects.
Pilot test
On your fuel, we repeat the engine-bench test at 1:20,000, with baseline runs first and treated runs after. The laboratory then puts a figure on your gain.
NTROPYX adds no energy to the fuel. It makes the engine turn a larger share of the fuel's energy into work.
Reports GBT104002131 and GBT104002132. The mechanism is our explanation: it lies outside the laboratory's accredited scope.
Both engines used less fuel and delivered more power.
The laboratory measured each engine at every load point of its regulatory cycle, with NTROPYX at 1:20,000.
Measured in the laboratory
| Scania DC13-114, 265 kW, EN 590 diesel, ESC cycle, at 1:20,000: 210 → 178 g/kWh, −15.2% | |
|---|---|
| Caterpillar C32, 890 kW, DMB marine diesel (1.80% S), E3 cycle, at 1:20,000: 235 → 200 g/kWh, −15.0% |
+17.5%
Average Scania power gain at 1:20,000. At load point A: 254 → 298 kW.
+18.0%
Average Caterpillar power gain at 1:20,000. At mode 1: 890 → 1,050 kW.
Each fuel-use reading lies within ±2.0% of the true value, 95 times in 100. For power: ±1.5%.
Reports GBT104002131 (Scania, ESC cycle) and GBT104002132 (Caterpillar, E3 cycle, ISO 8178-4). Expanded uncertainty, coverage factor k = 2.
Incomplete-combustion products fell far more than fuel use.
The laboratory measured these reductions at 1:20,000, on the ESC cycle (Scania) and the E3 cycle (Caterpillar).
Measured in the laboratory
| Smoke index (BSN) not stated by the laboratory | −81.7%−81.0% |
|---|---|
| Particulates (PM) ±8.0% | −68.6%−68.6% |
| Unburnt hydrocarbons (THC) ±5.0% | −64.7%−64.9% |
| Carbon monoxide (CO) ±3.0% | −44.8%−44.9% |
| Nitrogen oxides (NOx) ±3.0% | −20.0%−20.0% |
| Carbon dioxide (CO2) ±2.0% | −15.0%−15.0% |
Reports GBT104002131 and GBT104002132, laboratory CNAS L23122. Expanded uncertainty, coverage factor k = 2.
An accredited laboratory tested both engines.
Measured in the laboratory
Guangdong Baotong Quality Inspection, in Foshan, is accredited to ISO/IEC 17025 by CNAS (L23122), with ILAC-MRA recognition. The laboratory ran the tests without our involvement.
13-mode ESC cycle for the Scania, E3 cycle (ISO 8178-4) for the Caterpillar. Same engine, same fuel batch, same conditions: two baseline runs, then two treated runs.
The laboratory publishes its uncertainties and limits its results to the engines and batches tested. It signed both reports on 26 March 2026. We provide the raw readings on request.
Since 2015, we have also worked with road haulage customers. That statement comes from us, not from the laboratory reports.
The laboratory found no measurable change in the fuel.
Measured in the laboratory
11
fuel analyses before and after treatment, including GC-MS (ASTM D2425) and FTIR (ASTM E1252).
0
measurable change in the standard physico-chemical parameters.
52 → 56
cetane number of EN 590 road diesel at 1:20,000, measured on a CFR engine (ISO 5165). The treated fuel ignites earlier.
On the two diesels tested, NTROPYX is undetectable in the standardised physico-chemical analyses of the fuel.
Measured in the laboratory
The laboratory found no measurable change in density, viscosity, flash point, sulphur, water or ash. At 1:20,000, sulphur oxides fell in step with fuel use: 8.46 → 7.19 g/kWh on the Caterpillar. The sulphur content of the fuel stays the same.
Our approach
Chlorine, nitrogen, metals and stability remain those of your process. NTROPYX does not reformulate the fuel: its specification and sulphur content stay as you produce them.
Pilot test
On your fuel, we repeat these analyses before and after treatment.
Section 7 of reports GBT104002131 and GBT104002132.
Engines burn pyrolysis fuel less completely than diesel.
These are the quantities the laboratory measured with NTROPYX on diesel. On your fuel, we measure each one in the pilot test.
| Quantity | Measured on diesel at 1:20,000Measured in the laboratory | In pyrolysis fuelPublished studies | On your fuelPilot test |
|---|---|---|---|
| Fuel per kWh | −15.2% and −15.0% | An engine on PP oil used more fuel per kWh than on diesel (Pumpuang et al., 2024). A 20% tyre-oil blend gave the highest fuel use per kWh of the fuels tested (Mickevičius et al., 2024). | to measure |
| Power and efficiency | +17.5% and +18.0% | Blends of 10% and 20% tyre oil: brake thermal efficiency 3.6% and 4% lower than on diesel, at full load (Mickevičius et al., 2024). | to measure |
| CO and unburnt hydrocarbons | CO −44.8% and −44.9%; THC −64.7% and −64.9% | HDPE and PP oils: unburnt hydrocarbons above diesel at every load. CO above diesel for HDPE oil at every load, for PP oil at low and high load (Pumpuang et al., 2024). | to measure |
| Particulates and smoke | PM −68.6%; smoke −81.7% and −81.0% | HDPE and PP oils: more smoke than diesel (Pumpuang et al., 2024). Tyre oil: about 62.4% aromatics (Han et al., 2023). A 20% tyre-oil blend gave less smoke opacity than diesel at full load (Mickevičius et al., 2024). | to measure |
| NOx | −20.0% | HDPE oil: NOx above diesel at low and medium load. PP oil: below diesel at every load (Pumpuang et al., 2024). A 10% tyre-oil blend gave the highest NOx at full load (Mickevičius et al., 2024). | to measure, NO and NO2 separately |
| Cetane | 52 → 56 (EN 590) | Tyre oil: 39.94, compared with 51.4 for the diesel of the same study (EN ISO 5165) (Mickevičius et al., 2024). | to measure |
Not all oils fare worse: an engine running on HDPE oil reaches an efficiency close to diesel (Pumpuang et al., 2024). None of the study values is an NTROPYX measurement.
Our measured gain exceeds the energy gap with diesel.
Pyrolysis fuel differs from diesel by a few percent in energy content. NTROPYX adds no energy. It lets the engine turn more of the fuel's energy into work.
Published studies
−5.8%
Tyre oil: 40.49 MJ/kg lower heating value, compared with 43 for the diesel of the same study (Mickevičius et al., 2024).
−2.4%
Plastic oil: 41 MJ/kg calorific value, compared with 42 for diesel in the same comparison (Papari et al., 2021).
+0.4%
HDPE oil: 45.72 MJ/kg higher heating value. PP oil: 45.68. Diesel of the same study: 45.54 (Pumpuang et al., 2024).
Calculation
Percentages: our calculation from the values of each study. Compare values only within one study. LHV and HHV: heating value without and with the heat of water condensation.
- Measured in the laboratoryFuel saved per kWh with NTROPYX at 1:20,000, Scania DC13 on EN 590 diesel: 15.2%
- Published studiesTyre oil, energy below the diesel of the same study: 5.8%
- Plastic oil, energy below diesel: 2.4%
Pilot test
We measured this gain on diesel. On your pyrolysis fuel, we measure the actual figure in the pilot test.
Measured in the laboratory
20 to 32 °C
cooler exhaust under load, on both engines at 1:20,000, while power rose. In the laboratory's interpretation, a larger share of the fuel's energy becomes mechanical work instead of leaving as heat.
Report GBT104002131 (test-batch diesel).
We dose one litre for every 20,000 litres you fill.
NTROPYX is a clear, fully miscible liquid, added straight into the fuel.
We dose at your filling point: site storage tank, tanker truck or barge. Our technical team supervises the first dosing.
We install the dosing station away from electromagnetic fields: transformers, high-voltage lines and large motors. A pyrolysis plant draws high electrical power, so we choose the position with you.
A treated batch does not return to its untreated state. The contract states which batches you treat and how you label them.
1:20,000 is the dose rate of the laboratory tests.
One litre for 500,000 litres. More on request.
One 1 L bottle treats 10,000, 20,000, 50,000 or 500,000 litres, depending on its strength. Both test engines were dosed at 1:20,000, one of the standard bottle ratios.
We repeat the engine-bench test on your fuel.
Pilot test
- Baseline. Your untreated batch, measured first.
- Treated at 1:20,000. Measured after 2 hours of stabilisation at medium load.
- Sealed baseline. A fraction kept untreated, for the return to baseline at the end.
On diesel, the laboratory found no measurable difference between treated and untreated fuel. It measured the effect on the engine bench.
Illustrative photo.
We test four fuels.
- F0
- EN 590 diesel from a batch with a certificate of analysis, to repeat the existing bench result.
- F1
- Hydrotreated pyrolysis oil at 20% in EN 590 diesel.
- F2
- Distilled tyre oil at 10 to 20% in EN 590 diesel.
- F3
- PE/PP oil at 100%, if the laboratory accepts it.
You set the minimum useful gain in writing, before testing.
Pilot test
What we measure.
We measure fuel use by weight and by volume, and the engine's efficiency. We also measure power and torque at each mode, NOx, CO, THC, CO2, O2, particulates, smoke and exhaust temperature. We measure cetane and repeat the eleven fuel analyses before and after treatment. We add cylinder pressure, heat release, air flow and the heat carried off by the cooling circuit.
How often.
Three baseline runs and three treated runs per fuel. Each value comes with its margin, 95 times in 100.
When we report an effect.
We report an effect only if the difference exceeds the combined margin and keeps the same sign in every run. Otherwise, we report it as not shown. We promise no gain threshold.
You set the minimum useful gain with us and sign it before the test. The laboratory takes no part in that choice.
Combined margin = square root of (baseline margin² + treated margin²). Expanded uncertainty, coverage factor k = 2.
You reach a supply contract in four steps.
Our approach
Scoping.
Confidentiality agreement and complete analyses of your batch.
Pilot test.
Three baseline runs and three treated runs, with your minimum useful gain signed beforehand.
Report.
Signed report, raw readings for every mode, fuel certificates before and after, uncertainty budgets and calibration certificates.
Contract.
Dosing at your filling point, supervised commissioning and documentation, under a supply contract with Virgo Global Energy SA.
You choose the ISO/IEC 17025 laboratory. It runs the test without you or us taking part. We measure your gain in the pilot test, before any contract.